VMD-L Mailing List
From: John Stone (johns_at_ks.uiuc.edu)
Date: Fri Mar 20 2009 - 14:53:20 CDT
- Next message: Francesco Pietra: "vmd_plot"
- Previous message: Leandro Martínez: "Re: near clip"
- In reply to: Leandro Martínez: "Re: near clip"
- Next in thread: Schreiner Eduard: "Re: near clip"
- Reply: Schreiner Eduard: "Re: near clip"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
Leandro,
No, by translate, I meant that you can press the "t" key, and
translate the molecule away from the viewer (not changing atom
coordinates), in the Z direction using the alternate mouse button
John Stone
vmd_at_ks.uiuc.edu
On Fri, Mar 20, 2009 at 04:28:53PM -0300, Leandro Martínez wrote:
> Thanks John,
> That was more or less what I'm doing. The issue with
> playing with the display distance is that the movement
> controls become too sensitive, that is, when I reduce
> the display distance, a small movement in the mouse
> moves too much the molecules. This is nothing very
> serious though. When you say "translate the molecule" and
> then "scale it up", by "translate" you suggest actually
> changing its coordinates with "move molecule"?
> Thanks again,
> Leandro.
>
>
> On Fri, Mar 20, 2009 at 1:52 PM, John Stone <johns_at_ks.uiuc.edu> wrote:
>
> >
> > Hi,
> > No, it is not possible. OpenGL requires a front and rear clipping
> > plane at a hardware level, and they cannot be disabled, only set to
> > nearly zero (near) and nearly infinity (far).
> > If you want to get "closer" you can instead translate the molecule
> > farther away and then scale it up, and you can also change the combination
> > of display height/distance options to make the rendering look the
> > way you want. Let us know if you need more help with this.
> >
> > Cheers,
> > John
> >
> > On Fri, Mar 20, 2009 at 09:48:51AM -0300, Leandro Martínez wrote:
> > > Hello,
> > > Is it possible to fully deactivate the "near clipping"? Reducing
> > > it to its minimum in the Display Settings is not enough sometimes.
> > > One can zoom by changing the screen distance, but then the control
> > > over translation becomes too sensitive.
> > > Thanks,
> > > Leandro.
> >
> > --
> > NIH Resource for Macromolecular Modeling and Bioinformatics
> > Beckman Institute for Advanced Science and Technology
> > University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801
> > Email: johns_at_ks.uiuc.edu Phone: 217-244-3349
> > WWW: http://www.ks.uiuc.edu/~johns/ <http://www.ks.uiuc.edu/%7Ejohns/>
> > Fax: 217-244-6078
> >
-- NIH Resource for Macromolecular Modeling and Bioinformatics Beckman Institute for Advanced Science and Technology University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801 Email: johns_at_ks.uiuc.edu Phone: 217-244-3349 WWW: http://www.ks.uiuc.edu/~johns/ Fax: 217-244-6078
- Next message: Francesco Pietra: "vmd_plot"
- Previous message: Leandro Martínez: "Re: near clip"
- In reply to: Leandro Martínez: "Re: near clip"
- Next in thread: Schreiner Eduard: "Re: near clip"
- Reply: Schreiner Eduard: "Re: near clip"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]