Greetings to everyone
I calculated the non-bonded interactions (VdW and Electrostatic) between
two selections, using the same "cutoff" and "switch" distance as employed
in simulations:
============================================================================
namdenergy -vdw -elec -nonb -sel [atomselect top "segname AP1"] [atomselect
top "segname AP2"] -exe ../namd2 -extsys relaxation/equil_out.xsc -T 310
-switch 9 -cutoff 12 -pme -par ../martini-protein-bonds.par -par
./martini-protein-angles-cos.par -par ../martini-protein-dihedrals.par
-par ../martini-all-nonb.par -ofile "nonb_pep.dat"
============================================================================
However, when I tried to calculate the interaction energy within the
system:
============================================================================
namdenergy -elec -sel [atomselect top all] -exe ../namd2 -extsys
relaxation/equil_out.xsc -T 310 -switch 9 -cutoff 12 -pme -par
./martini-protein-bonds.par -par ../martini-protein-angles-cos.par -par
./martini-protein-dihedrals.par -par ../martini-all-nonb.par -ofile
"nonb_sys.dat"
============================================================================
I got the following error:
============================================================================
------------- Processor 0 Exiting: Called CmiAbort ------------
Reason: FATAL ERROR: Low global exclusion count! (266 vs 268) System
unstable or pairlistdist or cutoff too small.
FATAL ERROR: See http://www.ks.uiuc.edu/Research/namd/bugreport.html
Charm++ fatal error:
FATAL ERROR: Low global exclusion count! (266 vs 268) System unstable or
pairlistdist or cutoff too small.
FATAL ERROR: See http://www.ks.uiuc.edu/Research/namd/bugreport.html
============================================================================
Any insight regarding this error would be highly appreciated.
-- Cheers Peter
- Next message: Fotis Baltoumas: "Re: NAMD Energy Plugin: Cutoff error"
- Previous message: Mani Kandan: "SPC/E Water models"
- Next in thread: Fotis Baltoumas: "Re: NAMD Energy Plugin: Cutoff error"
- Reply: Fotis Baltoumas: "Re: NAMD Energy Plugin: Cutoff error"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]