From: Axel Kohlmeyer (akohlmey_at_gmail.com)
Date: Tue Dec 15 2009 - 03:40:07 CST
2009/12/15 Mert Gür <gurmert_at_gmail.com>:
> I believe due to our point of view ,our understanding of work potential is
> different. I still believe that water can be treated as an T,P reservoir
> since waters temperature and pressure is constant.
mert,
i think you are mistaken here. even if you use an NTP integration algorithm,
temperature and pressure are by far not constant. they fluctuate a lot. they
become constant only if you have an infinitely large system. for any finite
system, and particularly the (small) systems that you can treat in a typical
MD simulation, you need a quite long trajectory to average over in order
to approach a constant temperature or pressure requirement.
cheers,
axel.
> Best,
> Mert
>
>
-- Dr. Axel Kohlmeyer akohlmey_at_gmail.com Institute for Computational Molecular Science College of Science and Technology Temple University, Philadelphia PA, USA.